null

Furnace & HVAC

Furnace & HVAC

  • Product
  • Qty in Cart
  • Quantity
  • Price
  • Subtotal
  • Furnace part souls images

    Intermatic AG4803C3 AG SURGE PROTECTOR 277/480V

    Intermatic

    MSRP: $238.01
    Now: $183.92
    Intermatic AG4803C3 AG SURGE PROTECTOR 277/480V FurnacePartSource.com Commitment Always Brand-New Genuine Parts In stock parts ship Same Business Day when ordered by 5PM ET No Minimum Order Requirements unless noted...
    MSRP: $238.01
    Now: $183.92
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $238.01
    Now: $183.92
    Subtotal:
  • Furnace part souls images

    Intermatic GM40AV-W Autovoltage General Purpose Time Control 120-277V 40A DPDT 7DAY 24hour

    Intermatic

    MSRP: $202.97
    Now: $156.84
    Intermatic GM40AV-W Autovoltage General Purpose Time Control 120-277V 40A DPDT 7 DAY 24 hour FurnacePartSource.com Commitment Always Brand-New Genuine Parts In stock parts ship Same Business Day when ordered by 5PM...
    MSRP: $202.97
    Now: $156.84
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $202.97
    Now: $156.84
    Subtotal:
  • Furnace part souls images

    Intermatic FM/1QTUZ-120U 120V 24hr 7day SPDT QUARTZ

    Intermatic

    MSRP: $182.18
    Now: $140.77
    Intermatic FM/1QTUZ-120U 120V 24hr 7day SPDT QUARTZ  FurnacePartSource.com Commitment Item Typically Ships Within the Same Business Day Brand-New Genuine Parts - EverytimeNo Minimum Order Requirements
    MSRP: $182.18
    Now: $140.77
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $182.18
    Now: $140.77
    Subtotal:
  • Furnace part souls images Furnace part souls images

    Intermatic CD1024R COMPRESSOR DEFENDER

    Intermatic

    MSRP: $173.05
    Now: $133.72
    Intermatic CD1024R COMPRESSOR DEFENDER  FurnacePartSource.com Commitment Always Brand-New Genuine Parts In stock parts ship Same Business Day when ordered by 5PM ET No Minimum Order Requirements unless noted above
    MSRP: $173.05
    Now: $133.72
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $173.05
    Now: $133.72
    Subtotal:
  • Furnace part souls images

    Intermatic GM40AVE-RD89 24Hr/7Day 40A 120V-277V

    Intermatic

    MSRP: $240.17
    Now: $185.59
    Intermatic GM40AVE-RD89 24Hr/7Day 40A 120V-277V  FurnacePartSource.com Commitment Item Typically Ships Within the Same Business Day Brand-New Genuine Parts - EverytimeNo Minimum Order Requirements
    MSRP: $240.17
    Now: $185.59
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $240.17
    Now: $185.59
    Subtotal:
  • Furnace part souls images

    Intermatic T1905 125V SPDT 24HR TIMER

    Intermatic

    MSRP: $293.52
    Now: $226.81
    Intermatic T1905 125V SPDT 24HR TIMER  FurnacePartSource.com Commitment Item Typically Ships Within the Same Business Day Brand-New Genuine Parts - EverytimeNo Minimum Order Requirements
    MSRP: $293.52
    Now: $226.81
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $293.52
    Now: $226.81
    Subtotal:
  • Furnace part souls images

    Intermatic ET1105C 24HR 120/277V 30A SPST Elc tmr

    Intermatic

    MSRP: $435.63
    Now: $336.63
    Intermatic ET1105C 24HR 120/277V 30A SPST Elc tmr  FurnacePartSource.com Commitment Item Typically Ships Within the Same Business Day Brand-New Genuine Parts - EverytimeNo Minimum Order Requirements
    MSRP: $435.63
    Now: $336.63
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $435.63
    Now: $336.63
    Subtotal:
  • Furnace part souls images

    Intermatic CT2000 Percentage Cycle Timer

    Intermatic

    MSRP: $259.21
    Now: $200.30
    Intermatic CT2000 Percentage Cycle Timer FurnacePartSource.com Commitment Always Brand-New Genuine Parts In stock parts ship Same Business Day when ordered by 5PM ET No Minimum Order Requirements unless noted...
    MSRP: $259.21
    Now: $200.30
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $259.21
    Now: $200.30
    Subtotal:
  • Furnace part souls images

    Intermatic ET1705C 7 Day Time Switch 120-277 30A SPST

    Intermatic

    MSRP: $484.01
    Now: $374.01
    Intermatic ET1705C 7 Day Time Switch 120-277 30A SPST  FurnacePartSource.com Commitment Always Brand-New Genuine Parts In stock parts ship Same Business Day when ordered by 5PM ET No Minimum Order Requirements...
    MSRP: $484.01
    Now: $374.01
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $484.01
    Now: $374.01
    Subtotal:
  • Furnace part souls images Furnace part souls images

    Intermatic DTAV40E2 Defrost Timer 120/240V 50/60Hz 40a

    Intermatic

    MSRP: $271.01
    Now: $209.42
    Intermatic DTAV40E2 Defrost Timer 120/240V 50/60Hz 40a  FurnacePartSource.com Commitment Always Brand-New Genuine Parts In stock parts ship Same Business Day when ordered by 5PM ET No Minimum Order Requirements...
    MSRP: $271.01
    Now: $209.42
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $271.01
    Now: $209.42
    Subtotal:
  • Furnace part souls images

    Intermatic ET1725C ELECTRONIC TIMER 7DAY DPST

    Intermatic

    MSRP: $544.48
    Now: $420.74
    Intermatic ET1725C ELECTRONIC TIMER 7DAY DPST  FurnacePartSource.com Commitment Item Typically Ships Within the Same Business Day Brand-New Genuine Parts - EverytimeNo Minimum Order Requirements
    MSRP: $544.48
    Now: $420.74
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $544.48
    Now: $420.74
    Subtotal:
  • Furnace part souls images

    Intermatic T7401B 7-Day Mechanical Time Switch 120V 4PST W/OUT CARRYOVER

    Intermatic

    MSRP: $369.58
    Now: $285.59
    Intermatic T7401B 7-Day Mechanical Time Switch W/OUT CARRYOVER 120V 4PST FurnacePartSource.com Commitment Always Brand-New Genuine Parts In stock parts ship Same Business Day when ordered by 5PM ET No Minimum Order...
    MSRP: $369.58
    Now: $285.59
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $369.58
    Now: $285.59
    Subtotal:
  • Furnace part souls images

    Intermatic T7801B 7DAY Mechanical Time Switch 2NO/2NC 120V 40amp SWITCH

    Intermatic

    MSRP: $369.58
    Now: $285.59
    Intermatic T7801B 7DAY Mechanical Time Switch 2NO/2NC 120V 40amp SWITCH FurnacePartSource.com Commitment Always Brand-New Genuine Parts In stock parts ship Same Business Day when ordered by 5PM ET No Minimum Order...
    MSRP: $369.58
    Now: $285.59
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $369.58
    Now: $285.59
    Subtotal:
  • Furnace part souls images

    Intermatic MIL72EQTUZH-120 7Day FlushMt W/BatBackup&Ovrid

    Intermatic

    MSRP: $207.83
    Now: $160.60
    Intermatic MIL72EQTUZH-120 7Day FlushMt W/BatBackup&Ovrid  FurnacePartSource.com Commitment Item Typically Ships Within the Same Business Day Brand-New Genuine Parts - EverytimeNo Minimum Order Requirements
    MSRP: $207.83
    Now: $160.60
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $207.83
    Now: $160.60
    Subtotal:
  • Furnace part souls images

    Intermatic DTAV40 Defrost Timer 120/240V NEMA3R

    Intermatic

    MSRP: $187.90
    Now: $145.20
    Intermatic DTAV40 Defrost Timer 120/240V NEMA 3R  FurnacePartSource.com Commitment Always Brand-New Genuine Parts In stock parts ship Same Business Day when ordered by 5PM ET No Minimum Order Requirements unless...
    MSRP: $187.90
    Now: $145.20
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $187.90
    Now: $145.20
    Subtotal:
  • Furnace part souls images

    Hydrolevel 700SV 24vM/R LWCO 160#,W/ShortProbe

    Hydrolevel

    MSRP: $241.66
    Now: $183.08
    Hydrolevel 700SV 24vM/R LWCO 160#,W/ShortProbe  FurnacePartSource.com Commitment Item Typically Ships Within the Same Business Day Brand-New Genuine Parts - EverytimeNo Minimum Order Requirements
    MSRP: $241.66
    Now: $183.08
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $241.66
    Now: $183.08
    Subtotal:
  • Furnace part souls images

    Hydrolevel 250WC 120vPumpCtrl/LWCO w/WtrColumn

    Hydrolevel

    MSRP: $861.48
    Now: $665.69
    Hydrolevel 250WC 120vPumpCtrl/LWCO w/WtrColumn  FurnacePartSource.com Commitment Item Typically Ships Within the Same Business Day Brand-New Genuine Parts - EverytimeNo Minimum Order Requirements
    MSRP: $861.48
    Now: $665.69
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $861.48
    Now: $665.69
    Subtotal:
  • Furnace part souls images

    Hydrolevel VXTC-WF 120V FEEDER - NO METER

    Hydrolevel

    MSRP: $626.36
    Now: $484.00
    Hydrolevel VXTC-WF 120V FEEDER - NO METER  FurnacePartSource.com Commitment Item Typically Ships Within the Same Business Day Brand-New Genuine Parts - EverytimeNo Minimum Order Requirements
    MSRP: $626.36
    Now: $484.00
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $626.36
    Now: $484.00
    Subtotal:
  • Furnace part souls images

    Hydrolevel CGT450-2060 120vLWCO-15secDelay With ILT

    Hydrolevel

    MSRP: $346.12
    Now: $267.46
    Hydrolevel CGT450-2060 120vLWCO-15secDelay With ILT  FurnacePartSource.com Commitment Item Typically Ships Within the Same Business Day Brand-New Genuine Parts - EverytimeNo Minimum Order Requirements
    MSRP: $346.12
    Now: $267.46
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $346.12
    Now: $267.46
    Subtotal:
  • Furnace part souls images

    Hydrolevel 700 24vM/R LWCO 160#,30secLockout

    Hydrolevel

    MSRP: $320.26
    Now: $247.48
    Hydrolevel 700 24vM/R LWCO 160#,30secLockout  FurnacePartSource.com Commitment Item Typically Ships Within the Same Business Day Brand-New Genuine Parts - EverytimeNo Minimum Order Requirements
    MSRP: $320.26
    Now: $247.48
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $320.26
    Now: $247.48
    Subtotal:
  • Total: items /

Adding your products to cart

Furnace Replacement Parts & HVAC System Components 

Furnace replacement parts are critical to maintaining the performance and safety of any heating system. In both residential and commercial HVAC applications, a furnace relies on numerous components working together to heat air and circulate it throughout a building. These HVAC system components – from burners and heat exchangers to controls and sensors – must function correctly to ensure efficient operation and reliability. When any part fails or wears out, using quality replacement components (preferably OEM furnace parts) helps restore the system’s performance and prolong its lifespan. 

Key HVAC Components in Furnaces 

  • Blower Motors: The blower motor is an electric motor that drives a fan to circulate air through the furnace and ductwork. It pushes air across the heat exchanger to distribute warm air during heating, and also circulates air over the AC evaporator coil during cooling\. A properly functioning blower motor maintains airflow and consistent temperature throughout the space.
  • Ignition Modules & Ignitors: Modern furnaces use electronic ignition systems. An ignition module manages the sequence of operations for lighting the burner – it sends a spark or powers a hot-surface ignitor, opens the gas valve, and monitors the flame to ensure safe ignition. If the flame isn’t detected within a few seconds, the module will shut down the gas for safety. Hot surface ignitors (glow plugs) and spark ignitors work with the module to ignite the fuel reliably.
  • Limit Switches (Safety Controls): A limit switch is a temperature-activated safety device that prevents overheating. If the furnace’s internal temperature rises too high (for example, due to a blower failure or restricted airflow), the limit switch will open the circuit to shut off the burner. This protects the heat exchanger and other components from damage and is crucial for furnace safety. Many furnaces use a fan limit switch that also controls the blower fan on/off timing for heating. 
  • Control Boards: Often called furnace control boards or integrated furnace controllers, these are the “brains” of the furnace. Control boards regulate key functions like blower fan timing, ignition sequence, and gas valve operation. In some systems, a control board incorporates the ignition control as well, managing everything from the inducer fan and ignition spark to blower delays. A faulty control board can lead to various operational issues, so replacing it with the correct OEM board is important for proper furnace performance. 
  • Combustion Components (Burners & Sensors): The burners are where fuel combustion occurs to create heat, and they feed the heat exchanger. Replacing burners may be necessary if they become corroded or damaged. Additionally, flame sensors (or thermocouples in older units) are small but essential parts that detect the burner flame; if the flame sensor fails, the furnace may shut off the gas for safety. Maintaining these components ensures the furnace ignites correctly and operates safely. 

OEM Furnace Parts and Compatibility

 

When replacing furnace components, opting for OEM parts (Original Equipment Manufacturer parts) is often recommended. OEM furnace parts are made by the furnace’s manufacturer or an approved vendor to match the original specifications exactly. This guarantees proper fit and function within the system. Using OEM replacements provides “guaranteed compatibility” and reliability with the existing equipment. In contrast, generic or aftermarket parts might save cost upfront but can introduce compatibility issues – they may not align perfectly with the furnace’s design, potentially reducing efficiency or causing malfunctions. Moreover, nonOEM parts could even void manufacturer warranties in some cases. In summary, genuine OEM parts help ensure that the repaired furnace operates as intended, sustaining performance and safety standards set by the manufacturer.
 

Furnace Parts for Commercial HVAC Systems 

Commercial HVAC parts serve the same fundamental purposes as those in residential systems – moving air, igniting fuel, regulating temperature, etc. – but are often built for heavier duty and larger capacity. Commercial furnaces and rooftop units may use larger blowers, higher-output burners, and more robust heat exchangers to handle the heating demands of big spaces. They might also be configured as packaged units (especially in large buildings) where the furnace, blower, and AC components are integrated in one system. The parts themselves, however, still include familiar items like blower motors, ignition modules, sensors, limit switches, and control boards, just scaled up or reinforced for continuous operation. Using high-quality parts in commercial HVAC systems is critical: it ensures the system runs smoothly under intensive use, reducing energy waste and improving reliability. In fact, investing in quality commercial HVAC replacement parts can significantly enhance system performance and efficiency for businesses. Whether for a home furnace or an industrial heating unit, the goal in replacing parts is the same – to maintain safe operation and optimal heating performance. 

Frequently Asked Questions (FAQ) 

What are the most common furnace replacement parts? 

Common furnace replacement parts include blower motors, ignitors (hot surface ignitors or spark ignitors), ignition control modules, flame sensors, gas valves, and limit switches. These components frequently wear out or fail over time. For example, blower motors have moving parts that can burn out, and ignitors are fragile and crack with age. Control boards and thermostats may also require replacement if they malfunction. Keeping these parts in good working order is essential, as each plays a role in the furnace’s ability to heat effectively and run safely. 

How does a furnace limit switch improve safety? 

The limit switch is a safety device that monitors the furnace’s internal temperature. If the furnace gets too hot – for instance, if the blower motor isn’t moving enough
air to cool the heat exchanger – the limit switch opens the electrical circuit to shut off the burner. This prevents the furnace from overheating and potentially causing damage or creating a fire hazard. Once the furnace cools to a safe temperature, the switch resets (on many models) allowing normal operation to resume. In short, the limit switch protects both the equipment and your home by acting as an automatic safety cutoff.
 

What does a furnace ignition module do? 

An ignition module (sometimes called an ignition control) is an electronic component that controls the burner ignition process in a furnace. Its primary job is to light the burners safely. When the thermostat calls for heat, the ignition module initiates a sequence: it powers the ignitor or spark electrode and opens the gas valve to ignite the burner flame. The module also monitors the flame via a sensor. If a flame isn’t detected within a few seconds, the module will shut off the gas to prevent a dangerous gas buildupIn many modern furnaces, the ignition module is part of the main control board. A faulty ignition module can prevent the furnace from lighting at all, so replacing it promptly restores proper heating function. 

Why choose OEM furnace parts for replacements? 

OEM furnace parts are recommended because they ensure compatibility and original performance. OEM parts are made to the exact specifications of the furnace’s manufacturer, guaranteeing a precise fit and correct operation with the other components. This precise fit and high reliability mean the part will support the furnace’s efficiency and longevity as intended. By contrast, using aftermarket or “one-size-fits-all” parts can be a gamble – the part might physically fit, but it could have slight differences that lead to reduced efficiency or even system malfunctions. Additionally, OEM parts often carry better warranties and won’t risk voiding the furnace’s warranty. While they may cost a bit more initially, OEM parts often provide better long-term value by ensuring the furnace runs smoothly and reliably after repairs. 

Are commercial HVAC parts different from residential furnace parts? 

The fundamental parts of a furnace or HVAC system are similar in function whether in a home or a commercial building – both use blowers, burners/heat exchangers, filters, control systems, etc. The differences lie in scale, configuration, and durability. Commercial HVAC parts are typically larger, heavier-duty, and designed to handle greater heating/cooling loads continuously. For example, a commercial system might use multiple large blower motors or a bigger heat exchanger to serve a huge space, whereas a residential furnace has a single smaller blower for a house. Commercial units often use higher-voltage blowers or three-phase motors and may come as packaged units (combining AC and furnace in one rooftop box) for space and efficiency. Residential systems are usually split (separate furnace and AC) and lower capacity. Despite these differences, maintaining reliability and efficiency is crucial for both. Quality replacement parts are important in commercial systems because any downtime can affect many people and lead to high costs; similarly, in a home furnace, reliable parts keep the system running safely and efficiently. In summary, while the parts serve the same purposes, commercial HVAC parts are built for higher performance and tougher duty, and they must be matched to the specific requirements of the larger systems.