Furnace Pilot Assemblies & Pilot Systems
Shop furnace flame sensor replacement parts, pilot sensors, flame rods, and burner sensing components for compatible gas furnaces, boilers, and heating equipment. Furnace Part Source carries flame sensors from brands such as Rheem-Ruud, York, Amana-Goodman, Honeywell, Bard, Lochinvar, Eclipse, Siemens Combustion, Trane, and more.
Find replacement flame sensors by manufacturer, part number, furnace model, sensor rod length, or mounting style. Choose from brand-specific sensors, universal replacement options, pilot flame sensors, and flame detection assemblies. Before ordering, compare the original part number, rod shape, ceramic insulator, mounting bracket, electrical connection, and equipment compatibility. Check individual product listings for current prices, availability, and shipping options.
- Product
- Qty in Cart
- Quantity
- Price
- Subtotal
-
Rheem-Ruud AP14399D-2 Pilot Assembly - NG - W/R
Rheem-Ruud
MSRP: $43.00Now: $33.23Rheem-Ruud AP14399D-2 Pilot Assembly - NG - W/R FurnacePartSource.com CommitmentMSRP: $43.00Now: $33.23 -
Spence Engineering A85 AIR ADJUSTED PILOT A85 CI
Spence Engineering
MSRP: $1,990.00Now: $1,537.73Browning A85 87" Browning V Belt FurnacePartSource.com CommitmentMSRP: $1,990.00Now: $1,537.73 -
Williams Comfort Products P323073 Pilot/Generator Assembly
Williams Comfort Products
MSRP: $83.87Now: $64.81Williams Comfort Products P323073 Pilot/Generator Assembly FurnacePartSource.com CommitmentMSRP: $83.87Now: $64.81 -
Williams Comfort Products P323074 Nat Gas Pilot Assembly w/Ignitor
Williams Comfort Products
MSRP: $83.87Now: $64.81Williams Comfort Products P323074 Nat Gas Pilot Assembly w/Ignitor FurnacePartSource.com CommitmentMSRP: $83.87Now: $64.81 -
Lochinvar & A.O. Smith 100109290 (Replaces 9003531005) FV PILOT ASSEMBLY 180 DEG C
Lochinvar & A.O. Smith
MSRP: $182.75Now: $141.22Lochinvar & A.O. Smith 100109290 (Replaces 9003531005) FV PILOT ASSEMBLY 180 DEG CMSRP: $182.75Now: $141.22 -
Rheem-Ruud SP12596B Pilot Assembly
Rheem-Ruud
MSRP: $180.79Now: $139.70Rheem-Ruud SP12596B Pilot Assembly FurnacePartSource.com Commitment AlwaysMSRP: $180.79Now: $139.70 -
Utica-Dunkirk 14662098 Nat Gas Stand Pilot Assembly
Utica-Dunkirk
MSRP: $27.44Now: $21.20Htica-Dunkirk 14662098 Nat Gas Stand Pilot Assembly FurnacePartSource.com CommitmentMSRP: $27.44Now: $21.20 -
Trane PIT0026 Ignition Pilot Assembly R.H. NG Elec.
Trane
MSRP: $776.28Now: $599.85Trane PIT0026 Ignition Pilot Assembly R.H. NGMSRP: $776.28Now: $599.85 -
Robertshaw # 785-001 24/117V PILOT RELIGHT CONTROL
Robertshaw
MSRP: $127.08Now: $98.20Robertshaw # 785-001 24/117V PILOT RELIGHT CONTROL FurnacePartSource.com Commitment Item Typically Ships Within the Same Business Day Brand-New Genuine Parts – Every time No Minimum Order...MSRP: $127.08Now: $98.20 -
ASCO S104772EAX1 H10 Proof Of Closure Switch Spdt
Asco
MSRP: $2,768.95Now: $2,097.69ASCO S104772EAX1 H10 Proof Of Closure Switch Spdt FurnacePartSource.com Commitment Item Typically Ships Within the Same Business Day Brand-New Genuine Parts - EverytimeNo Minimum Order Requirements...MSRP: $2,768.95Now: $2,097.69 -
Emerson White Rodgers PG9A42JTL020 750 Mv Pilot Generator 90' R
Copeland Comfort Control (White Rodgers)
MSRP: $91.21Now: $70.48Emerson White Rodgers PG9A42JTL020 750 Mv Pilot Generator 90' R FurnacePartSource.com Commitment Item Typically Ships Within the Same Business Day Brand-New Genuine Parts - Everytime No Minimum...MSRP: $91.21Now: $70.48 -
ASCO PG9A41JTL020 750 Mv Pilot Generator 90' Left
Copeland Comfort Control (White Rodgers)
MSRP: $90.14Now: $69.65ASCO PG9A41JTL020 750 Mv Pilot Generator 90' Left FurnacePartSource.com Commitment Item Typically Ships Within the Same Business Day Brand-New Genuine Parts - EverytimeNo Minimum Order Requirements...MSRP: $90.14Now: $69.65 -
ASCO PG9A28JTL024 750 Mv Pilot Generator
Copeland Comfort Control (White Rodgers)
MSRP: $90.52Now: $69.95ASCO PG9A28JTL024 750 Mv Pilot Generator FurnacePartSource.com Commitment Item Typically Ships Within the Same Business Day Brand-New Genuine Parts - EverytimeNo Minimum Order RequirementsMSRP: $90.52Now: $69.95 -
ASCO PG9A27JTL022 750 Mv Pilot Geneator 90' R&L
Copeland Comfort Control (White Rodgers)
MSRP: $98.22Now: $75.90ASCO PG9A27JTL022 750 Mv Pilot Geneator 90' R&L FurnacePartSource.com Commitment Item Typically Ships Within the Same Business Day Brand-New Genuine Parts - EverytimeNo Minimum Order RequirementsMSRP: $98.22Now: $75.90 -
Rheem AE-60777-70 Pilot Tubing
Rheem
MSRP: $13.78Now: $10.44Rheem AE-60777-70 Pilot Tubing FurnacePartSource.com CommitmentMSRP: $13.78Now: $10.44
Furnace Pilot Assemblies and Gas Heating Pilot Systems
A furnace pilot assembly provides an ignition source for the main burner in gas heating equipment. Depending on the system, the assembly may include a pilot burner, thermocouple, thermopile, spark electrode, flame sensor, pilot tubing, or mounting bracket. These components work with the equipment's ignition and gas control system to support reliable burner operation.
Furnace Part Source carries replacement furnace pilot assemblies and related pilot system components for residential, commercial, and industrial heating applications. Available products include standing pilot assemblies, pilot and generator combinations, ignition pilot assemblies, pilot relight controls, millivolt pilot generators, and replacement pilot tubing.
Common Furnace Pilot System Parts We Carry
Common replacement parts for gas furnace pilot systems and related heating equipment include:
- Furnace pilot assemblies for providing an ignition flame to light the main burner in compatible gas heating systems.
- Standing pilot assemblies for older gas furnaces, boilers, and heating equipment designed to maintain a continuous pilot flame.
- Ignition pilot assemblies for equipment that uses an electronic ignition sequence to establish a pilot flame before the main burner operates.
- Pilot generator assemblies for millivolt heating systems that use heat from the pilot flame to produce electrical power for compatible gas controls.
- Pilot relight controls for compatible heating systems that monitor or restore pilot ignition according to the equipment's control sequence.
- Thermocouple and thermopile components for compatible pilot systems that use flame-generated electrical signals for gas valve operation or safety functions.
- Pilot tubing for supplying gas to the pilot burner in compatible furnace and heating applications.
- Replacement pilot assemblies with ignitors for systems that require a matched pilot burner and ignition electrode configuration.
Individual products may contain a complete assembly or a single replacement component. Check each listing to confirm what is included before ordering.
Standing Pilot Systems vs. Intermittent Pilot Ignition
Gas heating equipment can use different pilot ignition arrangements. The correct replacement depends on how the original system establishes a pilot flame, detects that flame, and controls gas flow.
Standing Pilot Light Systems
A standing pilot system maintains a small flame while the appliance is operating normally, including periods when the main burner is off. These systems are found on many older gas furnaces, boilers, wall heaters, and water heaters.
Standing pilot systems may use a thermocouple or thermopile heated by the pilot flame. Depending on the equipment, these components provide a flame-proving signal, millivolt power, or both. Replacement parts must match the original gas control and pilot assembly specifications.
Intermittent Pilot Ignition Systems
An intermittent pilot ignition system lights the pilot when the equipment receives a call for heat. After the pilot flame is established and verified, the ignition control can allow the main burner to operate. The pilot normally shuts off when the heating cycle ends.
These systems may use spark electrodes, flame-sensing components, and electronic ignition controls. A standing pilot assembly should not be substituted for an intermittent pilot assembly unless the equipment manufacturer specifically approves the replacement.
How to Find the Right Furnace Pilot Assembly
The best way to identify a replacement furnace pilot light assembly is to check the original component and the equipment data plate. Pilot assemblies can differ in burner shape, mounting position, gas orifice size, flame direction, tubing connections, ignition method, and electrical requirements.
On many furnaces, the model and serial number are printed on a rating plate inside the equipment cabinet or near an access panel. The existing pilot assembly may also have a manufacturer number or identification label.
Before ordering, compare:
- Original furnace pilot assembly part number
- Manufacturer and equipment model number
- Unit serial number
- Natural gas or LP propane configuration
- Standing pilot or intermittent pilot ignition system
- Pilot burner orientation and mounting bracket
- Pilot tubing size and connection type
- Thermocouple, thermopile, or flame sensor requirements
- Ignition electrode and wiring connections, when applicable
- Replacement or superseded part number
Pilot assemblies that look similar may have different gas orifices, mounting arrangements, or ignition components. Always use the equipment manufacturer's approved replacement or verified cross-reference rather than selecting a part by appearance alone.
Furnace Pilot Generators and Millivolt Controls
Some gas heating systems use a pilot generator, also called a thermopile, to produce electrical power from the heat of a pilot flame. These generators are commonly associated with millivolt gas control systems found in certain wall heaters, furnaces, boilers, and other gas-fired equipment.
Furnace Part Source carries pilot generator products such as 750 mV configurations from White-Rodgers and related control manufacturers. When replacing a pilot generator, confirm its part number, electrical output specification, mounting arrangement, connection type, and compatibility with the existing gas valve.
A pilot generator and a thermocouple are not automatically interchangeable. Their electrical characteristics and intended functions can differ, so the replacement must match the original equipment requirements.
Why a Furnace Pilot Light May Not Stay Lit
A furnace pilot light that will not ignite or remain lit may indicate a problem with the pilot assembly or another component in the gas control system. Common causes include a restricted pilot orifice, a damaged thermocouple, an incorrectly positioned flame sensor, a faulty ignition control, or an issue with gas supply or pressure.
Warning signs that may require professional inspection include:
- The pilot flame will not ignite.
- The pilot lights but goes out after the control is released.
- The pilot flame appears weak, unstable, or incorrectly positioned.
- The main burner does not ignite even when the pilot is established.
- An intermittent pilot system repeatedly attempts ignition without completing the heating cycle.
- The pilot assembly has visible damage, corrosion, or deteriorated connections.
These symptoms do not always mean the pilot assembly itself needs replacement. Gas valves, thermocouples, thermopiles, ignition modules, sensors, and other safety components can create similar problems. Have the system diagnosed before ordering replacement parts.
Gas pilot systems are safety-critical components. Installation, gas connection work, ignition adjustments, and repairs should be performed by a qualified technician following the equipment manufacturer's instructions.
Replacement Pilot Assemblies by Manufacturer
Furnace Part Source carries pilot system components from manufacturers including Rheem-Ruud, Williams Comfort Products, Utica-Dunkirk, Trane, Lochinvar, A.O. Smith, Robertshaw, and White-Rodgers. The catalog includes parts for different ignition arrangements, equipment types, and gas control configurations.
Examples include Rheem-Ruud pilot assemblies, Williams Comfort Products pilot/generator assemblies, Utica-Dunkirk natural gas standing pilot assemblies, Trane ignition pilot assemblies, Robertshaw pilot relight controls, and White-Rodgers pilot generators.
Some original pilot components may have updated replacement numbers. When searching for an older furnace pilot assembly, compare the original part number with the manufacturer's replacement documentation and the product listing before purchasing.
Need Help Matching a Furnace Pilot System Part?
Not sure which furnace pilot assembly, pilot generator, or ignition component fits your equipment? Gather the manufacturer name, model number, serial number, existing part number, and fuel type before ordering. Photos of the equipment rating plate and original pilot assembly can also help identify the correct component.
Contact Furnace Part Source for help locating a replacement pilot assembly or matching an older part number. Check individual product listings for current prices, availability, and shipping options.
Furnace Pilot System FAQs
What is a furnace pilot assembly?
A furnace pilot assembly contains the pilot burner and, depending on the design, may include an ignition electrode, thermocouple, thermopile, flame sensor, or mounting hardware. Its purpose is to provide an ignition source for the main burner in compatible gas heating equipment.
What is the difference between a pilot assembly and a pilot generator?
A pilot assembly provides the pilot flame used for burner ignition. A pilot generator, or thermopile, produces electrical power when heated by that flame. Some products combine both components into one assembly, while others are sold separately.
Are natural gas and propane pilot assemblies interchangeable?
Natural gas and LP propane pilot assemblies may use different orifice sizes and gas specifications. They should not be treated as interchangeable unless the equipment manufacturer provides an approved conversion or replacement procedure.
Why does my furnace pilot light keep going out?
A pilot light may go out because of a weak or improperly positioned flame, a thermocouple problem, a restricted pilot burner, a gas control issue, or another system fault. A qualified technician should identify the cause before parts are replaced.
Can I replace only the pilot assembly?
In some heating systems, the pilot assembly can be replaced separately from the gas valve or other ignition components. The correct repair depends on the equipment design, original part number, and diagnosis. Always confirm whether the replacement includes the burner, sensor, ignitor, and tubing needed for the application.
Can I find furnace pilot assemblies for older heating systems?
Replacement pilot assemblies and related components may still be available for older gas furnaces, wall heaters, boilers, and water heaters. Search using the original equipment model and part number, then verify any superseded or cross-referenced replacements.