null

Furnace & HVAC

Furnace & HVAC

  • Product
  • Qty in Cart
  • Quantity
  • Price
  • Subtotal
  • Furnace part souls images

    Cutler Hammer-Eaton C25DND325T Definite Purpose Contactor with Metal Mounting Plate

    Cutler Hammer-Eaton

    MSRP: $102.48
    Now: $79.19
    Cutler Hammer-Eaton C25DND325T Definite Purpose Contactor with Metal Mounting Plate 24Vac 50/60Hz Coil Voltage 3 Pole 25 Amps Open Type Enclosure Non-Reversing  FurnacePartSource.com Commitment Always Brand-New Genuine...
    MSRP: $102.48
    Now: $79.19
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $102.48
    Now: $79.19
    Subtotal:
  • Furnace part souls images

    Cutler Hammer-Eaton C25DND330B Definite Purpose Contactor with Metal Mounting Plate

    Cutler Hammer-Eaton

    MSRP: $118.26
    Now: $91.38
    Cutler Hammer-Eaton C25DND330B Definite Purpose Contactor with Metal Mounting Plate 208/240Vac 50/60Hz Coil Voltage 3 Pole 30 Amps Open Type Enclosure Non-Reversing    FurnacePartSource.com Commitment Always Brand-New...
    MSRP: $118.26
    Now: $91.38
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $118.26
    Now: $91.38
    Subtotal:
  • Furnace part souls images

    Cutler Hammer-Eaton C25DND330T Electrical, Contactor, 24Vac 50/60Hz Coil Voltage, 3 Pole, 30 Amps

    Cutler Hammer-Eaton

    MSRP: $118.26
    Now: $91.38
    Cutler Hammer-Eaton C25DND330T Definite Purpose Contactor with Metal Mounting Plate 24Vac 50/60Hz Coil Voltage 3 Pole 30 Amps Open Type Enclosure Non-Reversing    FurnacePartSource.com Commitment Always Brand-New Genuine...
    MSRP: $118.26
    Now: $91.38
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $118.26
    Now: $91.38
    Subtotal:
  • Furnace part souls images

    Cutler Hammer-Eaton C25DNF340A Definite Purpose Contactor with Metal Mounting Plate

    Cutler Hammer-Eaton

    MSRP: $138.19
    Now: $106.78
    Cutler Hammer-Eaton C25DNF340A Definite Purpose Contactor with Metal Mounting Plate 110/120Vac 50/60Hz Coil Voltage 3 Pole 40 Amps Open Type Enclosure Non-Reversing     FurnacePartSource.com Commitment ALWAYS...
    MSRP: $138.19
    Now: $106.78
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $138.19
    Now: $106.78
    Subtotal:
  • Furnace part souls images

    Cutler Hammer-Eaton C25BNB230T Definite Purpose Compact Contactor with Metal Mounting Plate

    Cutler Hammer-Eaton

    MSRP: $58.39
    Now: $45.12
    Cutler Hammer-Eaton C25BNB230T Definite Purpose Compact Contactor with Metal Mounting Plate Coil: 24Vac 50/60Hz  2 Pole 30 Amps Open Type Enclosure Non-Reversing    FurnacePartSource.com Commitment ALWAYS...
    MSRP: $58.39
    Now: $45.12
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $58.39
    Now: $45.12
    Subtotal:
  • Furnace part souls images

    Packard C340B 120V 40A 3P DP CONTACTOR

    Packard

    MSRP: $41.15
    Now: $31.80
    Packard C340B DP CONTACTOR Coil Voltage: 120V Amps: 40A 3 Pole Definite Purpose Contactor F/L Inductive Amps: 40 Foot Mount Accepts Aux. Switch: Yes Connection Type: Box Lug Hertz: 50/60 Includes lugs spade...
    MSRP: $41.15
    Now: $31.80
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $41.15
    Now: $31.80
    Subtotal:
  • Furnace part souls images

    Cutler Hammer-Eaton C320KG3 One Normally Open and One Normally Closed Side Mounted Auxiliary Contact

    Cutler Hammer-Eaton

    MSRP: $111.08
    Now: $85.83
    Cutler Hammer-Eaton C320KG3 Side Mounted Auxiliary Contact One Normally Open and One Normally Closed   Standard Pressure Plate Terminals for 15A-75A Definite Purpose Contactors   FurnacePartSource.com Commitment ALWAYS...
    MSRP: $111.08
    Now: $85.83
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $111.08
    Now: $85.83
    Subtotal:
  • Furnace part souls images

    Packard C350A 3 POLE CONTACTOR 50A 24V

    Packard

    MSRP: $94.07
    Now: $72.69
    Packard C350A 3 POLE CONTACTOR F/L Inductive Amps: 50A Coil Voltage: 24V Hertz: 50/60 Includes lugs spade terminals and covers Coils have class B insulation Locked Rotor Amps 240/480/600: 300/250/200 Number of...
    MSRP: $94.07
    Now: $72.69
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $94.07
    Now: $72.69
    Subtotal:
  • Furnace part souls images

    Modine 5H0750320000 HOT SURFACE IGNITOR

    Modine

    MSRP: $107.07
    Now: $82.73
    Modine 5H0750320000 HOT SURFACE IGNITOR   FurnacePartSource.com Commitment ALWAYS Brand-New Genuine Parts In stock parts ship SAME Business Day when ordered by 5PM ET No Minimum Order Requirements unless noted...
    MSRP: $107.07
    Now: $82.73
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $107.07
    Now: $82.73
    Subtotal:
  • Furnace part souls images Furnace part souls images

    Amana-Goodman B1368034S Blower Wheel CW 10" x 6"

    Amana-Goodman

    MSRP: $64.93
    Now: $50.17
    Amana-Goodman B1368034S Blower Wheel 10" x 6" CW Clockwise FurnacePartSource.com Commitment Always Brand-New Genuine Parts In stock parts ship Same Business Day when ordered by 5PM ET No Minimum Order Requirements unless noted above
    MSRP: $64.93
    Now: $50.17
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $64.93
    Now: $50.17
    Subtotal:
  • Furnace part souls images

    Packard PF52475 Transformer 120/208/240/480>24 75VA

    Packard

    MSRP: $83.95
    Now: $64.87
    Packard PF52475 Transformer 120/208/240/480>24 75VA   FurnacePartSource.com Commitment ALWAYS Brand-New Genuine Parts In stock parts ship SAME Business Day when ordered by 5PM ET No Minimum Order Requirements unless noted...
    MSRP: $83.95
    Now: $64.87
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $83.95
    Now: $64.87
    Subtotal:
  • Furnace part souls images Furnace part souls images

    Amana-Goodman 1370912S Auto Limit Switch 210-240F

    Amana-Goodman

    MSRP: $40.94
    Now: $31.63
    Amana-Goodman 1370912S 210-240F Auto Limit Switch 210-240F If out of stock, call or text 1.866.620.8417 for possible cross reference FurnacePartSource.com Commitment Always Brand-New Genuine Parts In stock parts ship Same Business Day...
    MSRP: $40.94
    Now: $31.63
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $40.94
    Now: $31.63
    Subtotal:
  • Furnace part souls images

    Packard C240A 2P 40A 24V 50/60hz Contactor

    Packard

    MSRP: $23.74
    Now: $18.35
    Packard C240A Contactor 2P    40A 24V 50/60hz   FurnacePartSource.com Commitment Item Typically Ships Within the Same Business Day Brand-New Genuine Parts - Every time No Minimum Order Requirements      
    MSRP: $23.74
    Now: $18.35
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $23.74
    Now: $18.35
    Subtotal:
  • Furnace part souls images

    Packard C340C CONTACTOR 3P 40A 208/240V COIL

    Packard

    MSRP: $40.97
    Now: $31.66
    Packard C340C CONTACTOR 3P 40A 208/240V COIL   FurnacePartSource.com Commitment Item Typically Ships Within the Same Business Day Brand-New Genuine Parts - Every time No Minimum Order Requirements      
    MSRP: $40.97
    Now: $31.66
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $40.97
    Now: $31.66
    Subtotal:
  • Furnace part souls images

    Cutler Hammer-Eaton C25DNF340T Electrical, Contactor, 24Vac 50/60Hz Coil Voltage, 3 Pole, 40 Amps

    Cutler Hammer-Eaton

    MSRP: $138.19
    Now: $106.78
    Cutler Hammer-Eaton C25DNF340T Electrical Contactor 24Vac 50/60Hz Coil Voltage 3 Pole 40 Amps Open Type Enclosure Non-Reversing Definite Purpose Contactor with Metal Mounting Plate   FurnacePartSource.com Commitment Item...
    MSRP: $138.19
    Now: $106.78
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $138.19
    Now: $106.78
    Subtotal:
  • Furnace part souls images

    Packard C340A 3 Pole DP Encl Contactor 24V 40A

    Packard

    MSRP: $40.97
    Now: $31.66
    Packard C340A 3 Pole DP Encl Contactor 24V 40A 3P DP Encl Contactor   FurnacePartSource.com Commitment Item Typically Ships Within the Same Business Day Brand-New Genuine Parts - Every time No Minimum Order...
    MSRP: $40.97
    Now: $31.66
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $40.97
    Now: $31.66
    Subtotal:
  • Furnace part souls images

    Lennox 88H15 HEAT EXCHANGER

    Lennox

    MSRP: $1,237.83
    Now: $937.75
    Lennox 88H15 HEAT EXCHANGER FurnacePartSource.com Commitment Always Brand-New Genuine Parts In stock parts ship Same Business Day when ordered by 5PM ET No Minimum Order Requirements unless noted above    
    MSRP: $1,237.83
    Now: $937.75
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $1,237.83
    Now: $937.75
    Subtotal:
  • Furnace part souls images

    Trane MOT09262 ECM Motor 120/240v 1/2hp

    Trane

    MSRP: $1,164.57
    Now: $899.89
    Trane MOT09262 ECM Motor 120/240v 1/2hp   FurnacePartSource.com Commitment Always Brand-New Genuine Parts In stock parts ship Same Business Day when ordered by 5PM ET No Minimum Order Requirements unless noted...
    MSRP: $1,164.57
    Now: $899.89
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $1,164.57
    Now: $899.89
    Subtotal:
  • Furnace part souls images

    Armstrong R45688-001 Electrode Ignitor

    Armstrong Furnace

    MSRP: $62.50
    Now: $48.30
    Armstrong R45688-001 Electrode Ignitor   FurnacePartSource.com Commitment Always Brand-New Genuine Parts In stock parts ship Same Business Day when ordered by 5PM ET No Minimum Order Requirements unless noted above
    MSRP: $62.50
    Now: $48.30
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $62.50
    Now: $48.30
    Subtotal:
  • Furnace part souls images

    Lennox 12K98 Induced Draft Blower

    Lennox

    MSRP: $108.78
    Now: $84.06
    Lennox 12K98 Induced Draft Blower FurnacePartSource.com Commitment Always Brand-New Genuine Parts In stock parts ship Same Business Day when ordered by 5PM ET No Minimum Order Requirements unless noted above    
    MSRP: $108.78
    Now: $84.06
    Qty in Cart: 0
    Quantity:
    Price:
    MSRP: $108.78
    Now: $84.06
    Subtotal:
  • Total: items /

Adding your products to cart

Furnace Replacement Parts & HVAC System Components 

Furnace replacement parts are critical to maintaining the performance and safety of any heating system. In both residential and commercial HVAC applications, a furnace relies on numerous components working together to heat air and circulate it throughout a building. These HVAC system components – from burners and heat exchangers to controls and sensors – must function correctly to ensure efficient operation and reliability. When any part fails or wears out, using quality replacement components (preferably OEM furnace parts) helps restore the system’s performance and prolong its lifespan. 

Key HVAC Components in Furnaces 

  • Blower Motors: The blower motor is an electric motor that drives a fan to circulate air through the furnace and ductwork. It pushes air across the heat exchanger to distribute warm air during heating, and also circulates air over the AC evaporator coil during cooling\. A properly functioning blower motor maintains airflow and consistent temperature throughout the space.
  • Ignition Modules & Ignitors: Modern furnaces use electronic ignition systems. An ignition module manages the sequence of operations for lighting the burner – it sends a spark or powers a hot-surface ignitor, opens the gas valve, and monitors the flame to ensure safe ignition. If the flame isn’t detected within a few seconds, the module will shut down the gas for safety. Hot surface ignitors (glow plugs) and spark ignitors work with the module to ignite the fuel reliably.
  • Limit Switches (Safety Controls): A limit switch is a temperature-activated safety device that prevents overheating. If the furnace’s internal temperature rises too high (for example, due to a blower failure or restricted airflow), the limit switch will open the circuit to shut off the burner. This protects the heat exchanger and other components from damage and is crucial for furnace safety. Many furnaces use a fan limit switch that also controls the blower fan on/off timing for heating. 
  • Control Boards: Often called furnace control boards or integrated furnace controllers, these are the “brains” of the furnace. Control boards regulate key functions like blower fan timing, ignition sequence, and gas valve operation. In some systems, a control board incorporates the ignition control as well, managing everything from the inducer fan and ignition spark to blower delays. A faulty control board can lead to various operational issues, so replacing it with the correct OEM board is important for proper furnace performance. 
  • Combustion Components (Burners & Sensors): The burners are where fuel combustion occurs to create heat, and they feed the heat exchanger. Replacing burners may be necessary if they become corroded or damaged. Additionally, flame sensors (or thermocouples in older units) are small but essential parts that detect the burner flame; if the flame sensor fails, the furnace may shut off the gas for safety. Maintaining these components ensures the furnace ignites correctly and operates safely. 

OEM Furnace Parts and Compatibility

 

When replacing furnace components, opting for OEM parts (Original Equipment Manufacturer parts) is often recommended. OEM furnace parts are made by the furnace’s manufacturer or an approved vendor to match the original specifications exactly. This guarantees proper fit and function within the system. Using OEM replacements provides “guaranteed compatibility” and reliability with the existing equipment. In contrast, generic or aftermarket parts might save cost upfront but can introduce compatibility issues – they may not align perfectly with the furnace’s design, potentially reducing efficiency or causing malfunctions. Moreover, nonOEM parts could even void manufacturer warranties in some cases. In summary, genuine OEM parts help ensure that the repaired furnace operates as intended, sustaining performance and safety standards set by the manufacturer.
 

Furnace Parts for Commercial HVAC Systems 

Commercial HVAC parts serve the same fundamental purposes as those in residential systems – moving air, igniting fuel, regulating temperature, etc. – but are often built for heavier duty and larger capacity. Commercial furnaces and rooftop units may use larger blowers, higher-output burners, and more robust heat exchangers to handle the heating demands of big spaces. They might also be configured as packaged units (especially in large buildings) where the furnace, blower, and AC components are integrated in one system. The parts themselves, however, still include familiar items like blower motors, ignition modules, sensors, limit switches, and control boards, just scaled up or reinforced for continuous operation. Using high-quality parts in commercial HVAC systems is critical: it ensures the system runs smoothly under intensive use, reducing energy waste and improving reliability. In fact, investing in quality commercial HVAC replacement parts can significantly enhance system performance and efficiency for businesses. Whether for a home furnace or an industrial heating unit, the goal in replacing parts is the same – to maintain safe operation and optimal heating performance. 

Frequently Asked Questions (FAQ) 

What are the most common furnace replacement parts? 

Common furnace replacement parts include blower motors, ignitors (hot surface ignitors or spark ignitors), ignition control modules, flame sensors, gas valves, and limit switches. These components frequently wear out or fail over time. For example, blower motors have moving parts that can burn out, and ignitors are fragile and crack with age. Control boards and thermostats may also require replacement if they malfunction. Keeping these parts in good working order is essential, as each plays a role in the furnace’s ability to heat effectively and run safely. 

How does a furnace limit switch improve safety? 

The limit switch is a safety device that monitors the furnace’s internal temperature. If the furnace gets too hot – for instance, if the blower motor isn’t moving enough
air to cool the heat exchanger – the limit switch opens the electrical circuit to shut off the burner. This prevents the furnace from overheating and potentially causing damage or creating a fire hazard. Once the furnace cools to a safe temperature, the switch resets (on many models) allowing normal operation to resume. In short, the limit switch protects both the equipment and your home by acting as an automatic safety cutoff.
 

What does a furnace ignition module do? 

An ignition module (sometimes called an ignition control) is an electronic component that controls the burner ignition process in a furnace. Its primary job is to light the burners safely. When the thermostat calls for heat, the ignition module initiates a sequence: it powers the ignitor or spark electrode and opens the gas valve to ignite the burner flame. The module also monitors the flame via a sensor. If a flame isn’t detected within a few seconds, the module will shut off the gas to prevent a dangerous gas buildupIn many modern furnaces, the ignition module is part of the main control board. A faulty ignition module can prevent the furnace from lighting at all, so replacing it promptly restores proper heating function. 

Why choose OEM furnace parts for replacements? 

OEM furnace parts are recommended because they ensure compatibility and original performance. OEM parts are made to the exact specifications of the furnace’s manufacturer, guaranteeing a precise fit and correct operation with the other components. This precise fit and high reliability mean the part will support the furnace’s efficiency and longevity as intended. By contrast, using aftermarket or “one-size-fits-all” parts can be a gamble – the part might physically fit, but it could have slight differences that lead to reduced efficiency or even system malfunctions. Additionally, OEM parts often carry better warranties and won’t risk voiding the furnace’s warranty. While they may cost a bit more initially, OEM parts often provide better long-term value by ensuring the furnace runs smoothly and reliably after repairs. 

Are commercial HVAC parts different from residential furnace parts? 

The fundamental parts of a furnace or HVAC system are similar in function whether in a home or a commercial building – both use blowers, burners/heat exchangers, filters, control systems, etc. The differences lie in scale, configuration, and durability. Commercial HVAC parts are typically larger, heavier-duty, and designed to handle greater heating/cooling loads continuously. For example, a commercial system might use multiple large blower motors or a bigger heat exchanger to serve a huge space, whereas a residential furnace has a single smaller blower for a house. Commercial units often use higher-voltage blowers or three-phase motors and may come as packaged units (combining AC and furnace in one rooftop box) for space and efficiency. Residential systems are usually split (separate furnace and AC) and lower capacity. Despite these differences, maintaining reliability and efficiency is crucial for both. Quality replacement parts are important in commercial systems because any downtime can affect many people and lead to high costs; similarly, in a home furnace, reliable parts keep the system running safely and efficiently. In summary, while the parts serve the same purposes, commercial HVAC parts are built for higher performance and tougher duty, and they must be matched to the specific requirements of the larger systems.