HVAC Valves & Pumps
Shop furnace flame sensor replacement parts, pilot sensors, flame rods, and burner sensing components for compatible gas furnaces, boilers, and heating equipment. Furnace Part Source carries flame sensors from brands such as Rheem-Ruud, York, Amana-Goodman, Honeywell, Bard, Lochinvar, Eclipse, Siemens Combustion, Trane, and more.
Find replacement flame sensors by manufacturer, part number, furnace model, sensor rod length, or mounting style. Choose from brand-specific sensors, universal replacement options, pilot flame sensors, and flame detection assemblies. Before ordering, compare the original part number, rod shape, ceramic insulator, mounting bracket, electrical connection, and equipment compatibility. Check individual product listings for current prices, availability, and shipping options.
Shop HVAC valves and pumps for furnaces, boilers, air conditioners, refrigeration equipment, and hydronic heating systems. Furnace Part Source carries replacement gas valves, solenoid valves, ball valves, globe valves, zone valves, valve actuators, regulators, circulator pumps, and related components from brands such as Danfoss, York, ASCO, Siemens, Belimo, Maxitrol, Johnson Controls, and more.
Use the product list below to find HVAC valves and replacement parts by manufacturer, OEM part number, or component type. For pumps, check the required flow rate, voltage, head rating, and connections. For valves, confirm the fluid or gas type, pressure rating, connection size, operating voltage, and control function. Always verify equipment compatibility before ordering.
- Product
- Qty in Cart
- Quantity
- Price
- Subtotal
-
Rheem-Ruud BK171UL (Replacement for CB151UL) Beckett Condensate Pump
BECKETT PUMPS
MSRP: $78.90Now: $60.97Rheem-Ruud BK171UL (Replacement for CB151UL) Beckett Condensate Pump This is the Direct Replacement for CB151ULMSRP: $78.90Now: $60.97 -
Itron-Actaris B34SR-1 1/2-11/17 1.5" 5/8"x3/4" ORF 11-17" W.C.
Itron-Actaris
MSRP: $1,062.37Now: $820.92Itron-Actaris B34SR-1 1/2-11/17 1.5" 5/8"x3/4" ORF 11-17" W.C. FurnacePartSource.com Commitment Item Typically Ships Within the Same Business Day Brand-New Genuine Parts - Everytime No...MSRP: $1,062.37Now: $820.92 -
Wayne Combustion 62374-004 (Replacement for VR8305M4801) Gas Valve F/HSG,P250AF & P265F
Wayne Combustion
MSRP: $288.60Now: $223.01Wayne Combustion 62374-004 (Replacement for VR8305M4801) Gas Valve F/HSG,P250AF & P265F This is the Identical Replacement for VR8305M4801 FurnacePartSource.com Commitment Item Typically Ships...MSRP: $288.60Now: $223.01 -
Tekmar Controls 306V 6 ZONE VALVE CONTROL PANEL
Tekmar Controls
MSRP: $395.84Now: $305.87Tekmar Controls 306V 6 ZONE VALVE CONTROL PANEL FurnacePartSource.com Commitment Item Typically Ships Within the Same Business Day Brand-New Genuine Parts - Every Time No Minimum...MSRP: $395.84Now: $305.87 -
Trane VAL9377 Slow Open Nat Gas Valve 24V 3/4"
Trane
MSRP: $1,838.89Now: $1,420.96Trane VAL9377 Slow Open Nat Gas Valve 24V 3/4"MSRP: $1,838.89Now: $1,420.96 -
Amana-Goodman 0151M00027SK Gas Valve 24V 2Stage 3.5"WC
Amana-Goodman
Amana-Goodman 0151M00027SK Gas Valve 24VQty in Cart: 0Price:Subtotal: -
Eclipse 501230 4"NPT FULL PORT BUTTERFLY VLV
Eclipse
MSRP: $1,363.02Now: $1,053.24Eclipse 501230 4"NPT FULL PORT BUTTERFLY VLV FurnacePartSource.com Commitment Item Typically Ships Within the Same Business Day Brand-New Genuine Parts - Everytime No Minimum Order...MSRP: $1,363.02Now: $1,053.24 -
Danfoss 032L1209 Solenoid Valve 1/2"ODF EVR6 N/C
Danfoss
MSRP: $110.78Now: $85.60Danfoss 032L1209 Solenoid Valve 1/2"ODFMSRP: $110.78Now: $85.60 -
Johnson Controls VA-7700-GGA-2 24V NSR PROPORTIONAL VALVE ACT
Johnson Controls
MSRP: $546.45Now: $422.25Johnson Controls VA-7700-GGA-2 24V NSR PROPORTIONAL VALVE ACT FurnacePartSource.com CommitmentMSRP: $546.45Now: $422.25 -
Lennox 75M49 (Replaces 28W48) 24V Solenoid for Reversing Valve
Lennox
MSRP: $62.29Now: $48.13Lennox 75M49 (Replaces 28W48) 24V Solenoid for Reversing Valve This is the Direct Replacement for 28W48 FurnacePartSource.com Commitment Item Typically Ships Within the Same Business...MSRP: $62.29Now: $48.13 -
Residio VR8205Q2795T (Replaces VR8205Q2795) 1/2" 24V 2Stg Direct Ignition Gas Valve
Resideo
MSRP: $292.51Now: $226.03Residio # VR8205Q2795T (replaces VR8205Q2795) 1/2" 24V 2Stg Direct Ignition Gas Valve This is the Updated Version of VR8205Q2795 FurnacePartSource.com Commitment Item TypicMSRP: $292.51Now: $226.03 -
International Comfort Products # 1190408 24v 3.5" wc Nat 1/2" Gas Valve
Sensus-Gas Division
MSRP: $19.78Now: $15.29International Comfort Products # 1190408 24v 3.5" wc Nat 1/2" Gas Valve FurnacePartSource.com Commitment Item Typically Ships Within the Same Business Day Brand-New Genuine Parts – Every...MSRP: $19.78Now: $15.29 -
Siemens Industrial Controls 3SU1400-1AA10-1CA0 CONTACT BLOCK 1NC FRONT MOUNT
Siemens Industrial Controls
MSRP: $22.09Now: $17.07Siemens Industrial Controls 3SU1400-1AA10-1CA0 CONTACT BLOCK 1NC FRONT MOUNT FurnacePartSource.com Commitment Item Typically Ships Within the Same Business Day Brand-New Genuine Parts - Every...MSRP: $22.09Now: $17.07 -
Sensus-Gas Division 243-RPC-B-2F 2"FlgRegIntCtrlLine3-15#3/4"30
Sensus-Gas Division
MSRP: $4,074.49Now: $3,148.47Sensus-Gas Division 243-RPC-B-2F 2"FlgRegIntCtrlLine3-15#3/4"30 FurnacePartSource.com Commitment Item Typically Ships Within the Same Business Day Brand-New Genuine Parts - Everytime No...MSRP: $4,074.49Now: $3,148.47 -
Johnson Controls VG1245FT+910HGA Valve, Assembly, 2", NPT, 0-10Vdc, 2-10Vdc, 24Vac
Johnson Controls
MSRP: $541.88Now: $410.51Johnson Controls VG1245FT+910HGA Valve, Assembly, 2", NPT, 0-10Vdc, 2-10Vdc, 24Vac FurnacePartSource.com Commitment Item Typically Ships Within the Same Business Day Brand-New Genuine Parts -...MSRP: $541.88Now: $410.51 -
Kromschroder 88001852 2"NPT GAS SOLENOID VLV 120VAC
Kromschroder
MSRP: $1,198.21Now: $925.89Kromschroder 88001852 2"NPT GAS SOLENOID VLV 120VAC FurnacePartSource.com Commitment Item Typically Ships Within the Same Business Day Brand-New Genuine Parts - Everytime No Minimum Order...MSRP: $1,198.21Now: $925.89 -
Maxon 600HMA11BA11BB33A0 Valve, Gas, 6", ANSI Flanged, High Capacity Flow, 2 Way Normally Closed
Maxon
MSRP: $26,708.22Now: $20,233.50Maxon 600HMA11BA11BB33A0 Valve, Gas, 6", ANSI Flanged, High Capacity Flow, 2 Way Normally Closed FurnacePartSource.com Commitment Item Typically Ships Within the Same Business Day Brand-New...MSRP: $26,708.22Now: $20,233.50 -
Maxitrol 325-5-3/4 (Replaces 325-5A-3/4) Gas Regulator with Positive Dead-End Lock-Up
Maxitrol
MSRP: $65.95Now: $50.96Maxitrol 325-5-3/4 (Replaces 325-5A-3/4) Gas Regulator with Positive Dead-End Lock-Up 3/4" NPT, 10 PSI Max Inlet Pressure, 4-12"wc Outlet Pressure, 325,000 btu/hr Max Capacity Lever Acting Design...MSRP: $65.95Now: $50.96 -
Carrier 340620-720 (Replaces 340620-755) TXV KIT REPLACEMENT
Carrier
MSRP: $173.02Now: $133.70Carrier 340620-720 TXV KIT REPLACEMENT This is the direct replacement for 340620-755 FurnacePartSource.com Commitment Item Typically Ships Within the Same Business DayMSRP: $173.02Now: $133.70 -
Resideo VR8305Q4153T 3/4" 24V 2Stg DirctIgn GasVlv
Resideo
MSRP: $293.37Now: $226.70Resideo VR8305Q4153T 3/4" 24V 2Stg DirctIgn GasVlv FurnacePartSource.com Commitment Item Typically Ships Within the Same Business Day Brand-New Genuine Parts - Everytime No Minimum Order...MSRP: $293.37Now: $226.70
HVAC Valves and Pumps for Heating and Cooling Systems
HVAC valves and pumps control the movement of natural gas, propane, refrigerant, water, and condensate throughout heating and cooling equipment. These components perform different functions depending on the system, from regulating fuel delivery to a furnace burner to circulating hot water through a boiler or removing condensate from an air conditioner.
Furnace Part Source carries a range of HVAC replacement valves, pumps, and related control components for residential, commercial, and industrial equipment. Our catalog includes furnace gas valves, HVAC solenoid valves, ball valves, check valves, globe valves, valve actuators, gas regulators, zone valves, circulator pumps, condensate pumps, and specialized valve assemblies. Search by manufacturer, part number, or component type to find a replacement that matches your equipment.
Common HVAC Valves and Pump Parts We Carry
Different HVAC systems require specific valves and pumps to manage fuel, refrigerant, water circulation, and automatic control. Common replacement components include:
- Furnace and HVAC gas valves for controlling natural gas or propane delivery to burners in compatible furnaces, boilers, and heating equipment.
- Solenoid valves for electrically controlled opening and closing of gas, refrigerant, water, or other approved fluids.
- Ball valves and check valves for flow isolation and preventing reverse flow in compatible piping and refrigeration applications.
- Globe valves and control valves for regulating fluid flow in heating, cooling, and building automation systems.
- Zone valves and valve actuators for controlling water flow to individual heating or cooling zones in hydronic systems.
- Gas pressure regulators for maintaining the required downstream gas pressure within the manufacturer's specified operating range.
- Circulator pumps for moving water through boilers, radiators, baseboard heaters, radiant floor loops, and other hydronic systems.
- Condensate pumps for removing collected condensation from high-efficiency furnaces, air handlers, air conditioners, and other compatible equipment.
- Valve bodies, replacement coils, and actuator components for servicing compatible valve assemblies without replacing unrelated system components.
Furnace Gas Valves and HVAC Gas Control Valves
A furnace gas valve controls the supply of fuel to the burner during the heating cycle. Depending on the equipment, the valve may work with an ignition control board, pilot system, flame safety circuit, or other combustion controls. Gas valves are used in residential furnaces, commercial heating equipment, boilers, water heaters, and industrial burner applications.
When selecting a replacement gas valve, compare the original manufacturer part number, natural gas or propane application, inlet and outlet pressure requirements, voltage, connection size, ignition system, and control configuration. Some equipment uses single-stage valves, while other systems require two-stage, modulating, or specialized gas control valves.
A furnace that fails to ignite, shuts down during startup, or does not receive the correct gas supply may have a gas valve problem. However, similar symptoms can result from ignition controls, pressure switches, wiring, flame sensors, or other safety components. Gas valve diagnosis and replacement should be handled by a qualified HVAC professional.
HVAC Solenoid Valves and Automatic Flow Controls
HVAC solenoid valves use an electrically operated coil to control the opening or closing of a valve. Depending on the valve design and its approved application, solenoid valves may control refrigerant, water, fuel gas, or other fluids in heating, cooling, and process equipment.
Common configurations include normally closed, normally open, two-way, and three-way solenoid valves. Before ordering, confirm the original part number, coil voltage, valve port size, pressure range, flow requirements, operating medium, and valve configuration.
For example, an ASCO solenoid valve designed for a specific gas shutoff application should not be replaced with a valve intended only for water or refrigerant service. The replacement must be rated for the intended medium and equipment operating conditions.
Zone Valves, Globe Valves, and Hydronic Heating Controls
Zone valves regulate water flow through individual areas of a hydronic heating or cooling system. In systems with multiple thermostats or heating zones, a zone valve opens or closes to direct water through the appropriate piping loop, radiator, baseboard heater, or radiant floor circuit.
Globe valves and motorized control valves are also used in HVAC equipment to regulate water or other approved fluid flow. Some valves use electric or pneumatic actuators that respond to temperature controls, building automation systems, or equipment operating signals.
When replacing a zone valve, globe valve, or actuator, check the valve body size, connection type, voltage, actuator model, control signal, flow coefficient, and operating pressure. If only the actuator or power head has failed, a compatible replacement component may be available separately from the valve body.
Circulator Pumps and Condensate Pumps
HVAC pumps perform different functions depending on the equipment and application. Two common types are circulator pumps and condensate pumps.
Circulator pumps move water through a hydronic heating or cooling circuit. They are commonly used with boilers, radiant floor heating, radiators, baseboard heating systems, and commercial water circulation equipment. Replacement selection depends on flow rate, pump head, horsepower, voltage, pipe connections, and system requirements.
Condensate pumps remove water collected during normal cooling operation or from compatible high-efficiency heating equipment. They are often used when gravity drainage is not practical, such as in certain basement, attic, or mechanical-room installations. Replacement considerations include voltage, pumping capacity, maximum lift, reservoir design, discharge connections, and installation space.
A circulator pump cannot be substituted for a condensate pump because the two products are designed for different applications. Always match the replacement pump to the original equipment and operating requirements.
How to Choose the Right HVAC Valve or Pump Replacement
The best way to find a replacement HVAC valve or pump is to start with the manufacturer part number on the existing component. Valves and pumps can vary significantly in their operating specifications, even when they look similar or are manufactured by the same company.
Before ordering, compare:
- Original manufacturer or OEM part number
- Replacement or superseded part number
- Equipment brand, model number, and serial number
- Component type and intended application
- Natural gas, propane, refrigerant, water, or other approved operating medium
- Voltage, electrical connections, and control signal
- Inlet and outlet connection sizes
- Operating pressure range and temperature limits
- Flow capacity, Cv rating, or GPM rating when applicable
- Pump head rating, horsepower, mounting style, and discharge requirements
- Normally open, normally closed, modulating, or other valve operating configuration
If the original part has been discontinued, check manufacturer documentation for an approved replacement or cross-reference. A matching connection size or similar appearance does not confirm compatibility. This is especially important for gas valves, fuel shutoff controls, high-pressure valves, and electrical actuators.
Replacement Valves and Pumps by Manufacturer
Furnace Part Source carries HVAC valves and pump-related products from a range of equipment and component manufacturers. Available listings include products from Danfoss, York, Bradford White, ASCO, Siemens Building Technologies, Belimo, Maxitrol, Johnson Controls, Parker Fluid Control, Copeland Comfort Control, Weil-McLain, and other manufacturers.
These brands manufacture different types of valves, actuators, regulators, controls, and pump components for specific equipment applications. Not every manufacturer offers interchangeable parts, and similar products may have different operating ratings.
Check each product listing for its part number, specifications, current price, availability, and shipping options. For OEM or replacement components, verify that the listed part is suitable for the equipment being repaired.
When Should an HVAC Valve or Pump Be Replaced?
An HVAC valve or pump may need service when it no longer controls flow correctly, develops a leak, fails to respond to a control signal, produces unusual operating noise, or cannot maintain the required system performance. Symptoms depend on the component and the equipment in which it is installed.
Possible warning signs include:
- A furnace that fails to ignite or complete its heating cycle.
- A solenoid valve that does not respond to the correct electrical signal.
- Uneven heating in a hydronic system caused by inadequate circulation or a valve that fails to open.
- A zone that continues heating when its zone valve should be closed.
- Unusual noise, leakage, or reduced flow from a circulator pump.
- Condensate collecting around equipment because the drainage system is not removing water.
- A valve actuator that does not move the valve through its required operating range.
These symptoms may also result from electrical problems, blocked piping, faulty sensors, control board issues, or other equipment failures. Confirm the cause before replacing a component. Gas piping, refrigerant circuits, and safety-related controls should be serviced by appropriately qualified technicians.
Need Help Finding the Right HVAC Valve or Pump?
Not sure which HVAC valve, furnace gas valve, solenoid valve, zone valve, circulator pump, or condensate pump you need? Start with the manufacturer's part number and the equipment model number. Check the existing component label for voltage, pressure ratings, connection size, and other operating specifications.
You can also contact Furnace Part Source for help identifying a replacement. Providing photos of the existing part label, equipment data plate, and any manufacturer cross-reference information can help narrow the search and reduce the chance of ordering an incompatible component.
HVAC Valves and Pumps FAQs
What types of valves are used in HVAC systems?
HVAC systems use different valves depending on the application, including furnace gas valves, solenoid valves, ball valves, check valves, globe valves, zone valves, pressure regulators, and motorized control valves. Each type performs a specific function involving fuel, refrigerant, water flow, or system control.
What does a gas valve do in a furnace?
A furnace gas valve controls the delivery of natural gas or propane to the burner as part of the equipment's ignition and safety sequence. The correct replacement must match the furnace model, fuel type, operating pressure, voltage, ignition configuration, and manufacturer requirements.
What is the difference between a gas valve and a solenoid valve?
A gas valve is designed to control fuel gas flow, while a solenoid valve describes a valve operated by an electromagnetic coil. Some gas valves use solenoids, but not every solenoid valve is approved for gas service. Always check the valve's intended operating medium and safety ratings.
What is the difference between a circulator pump and a condensate pump?
A circulator pump moves water through a hydronic heating or cooling system, while a condensate pump removes collected condensation from HVAC equipment. These pumps have different designs, performance requirements, and applications.
How do I choose the right HVAC condensate pump?
Match the replacement condensate pump to the equipment's drainage requirements. Check voltage, pumping capacity, maximum vertical lift, discharge connection size, reservoir configuration, and available installation space. Use the original part number or manufacturer specifications when possible.
What does a zone valve do in a heating system?
A zone valve controls water flow to a specific section of a hydronic heating system, such as a radiator circuit, baseboard heating loop, or radiant floor zone. It generally responds to a thermostat or heating control signal to open or close the flow path.
Are furnace gas valves interchangeable between brands?
Furnace gas valves should not be treated as interchangeable unless the replacement is approved for the specific equipment and application. The correct valve must match the fuel type, pressure range, electrical rating, ignition configuration, connection size, and manufacturer requirements.
Can I replace just a valve actuator or solenoid coil?
Some HVAC valves allow an actuator, solenoid coil, or power head to be replaced separately. This depends on the valve design and manufacturer. Match the replacement component to the exact valve model and part number before ordering.
Where can I find the part number on an HVAC valve or pump?
The part number is commonly printed on a manufacturer label, metal nameplate, actuator housing, coil label, or pump body identification plate. If the label is unreadable, check the equipment service manual or parts documentation and confirm the model number before selecting a replacement.